Annual Energy Savings from Base Case

This is the differential energy use in kBtu per square foot of glass between the generic base case and a selected product(s). The base case window properties are defined in the table below.

All annual energy performance data are given as energy use per perimeter zone floor area (e.g., kWh/sf-yr or kBtu/sf-yr). The perimeter zone is a 10-foot-wide-office space extending 15 feet from the window with a ceiling height of 9 feet and a total floor-to-floor height of 12 feet.

Total annual electricity use (site energy) includes the following electricity end uses: lighting, cooling, and fans for supply, and returns for ventilation, heating, and cooling.

Construction TypeWindow SHGC Tvis U-value
NewDouble Clear, Air Filled 0.70 0.79 0.47
Replacement1/4" Monolithic 0.82 0.86 1.03

The effect of excessive air infiltration through existing operable windows is added to COMFEN-calculated energy savings for each replacement window comparison base case. Click here to review air infiltration calculation methodology and assumptions.

Annual Energy Savings are based on source energy.